wastek PRO

A control panel for a small well?
Wastek Pro is designed to fit into small spaces. The peculiarity of this control panel is the possibility to use an air pressure sensor, particularly useful when the installation site is a small well.
Wastek Pro allows an accurate level detection from 0 to 100 cm and is expandable with a range of connectivity modules.
SIMPLE CONTROL
Voltage, current and phase control guaranteed
ACCURACY
Level reading and setting up to 1 cm
SPACE EFFICIENCY
Suitable for use in small wells, air sensor replaces up to 4 floats
ACCESSORIES
Acoustic alarm included
From 469 €
EASY INSTALLATION
EXPANDABILITY
USER INTERFACE
VERSATILITY
MAIN FEATURES
MAIN FEATURES
- LCD display for displaying and programming: voltage, current, power factor, hours of operation, number of starts, motor status, alarms, sensor signal and thresholds
- AUTOMATIC - 0 (standby) – MANUAL pushbuttons (fixed or pulse)
- Language settings (Italian, English, French, Spanish, German)
- Dry running protection by: level probes/floats/pressure switches and minimum current
- Up to 4 control inputs: floats/pressure switches
- Input for air sensor and 4-20 mA or 0-10V analogue signal
- Unit of measurement of analog signal: centimetres or metres
- Clicson inputs with automatic reset (can be disabled)
- Inputs inversion (from normally open to normally closed)
- Automatic reset from minimum current alarm settable with 4 programmable times
- Start-up and shutdown delay time (programmable)
- Maintenance time control (programmable
- Pushbutton for manual operation (fixed or pulse)
- Provision for run capacitors on single-phase model (not included)
ADDITIONAL FUNCTIONS WASTEK PRO 2
- Duty/standby (can be disabled)
- Immediate motor changeover in case of a fault

VERSIONS
- Power supply 1 phase 100-240Vac 50/60Hz (EASY-Mono)
- Power supply 3 phase 310-450Vac 50/60Hz (EASY-Tri/5.5)
CONTROLS
- Electronic control of minimum and maximum voltage
- Electronic control of maximum motor current
- Electronic minimum motor current control
- Failure or incorrect phase sequence control on power supply input (can be disabled)
ALARMS
- Alarms reported: voltage status, levels, motor overload, minimum current, clicson motor
- System maintenance warning
- Alarm output contacts
PROTECTIONS
- Auxiliary and motor protection fuses
- Isolator (except for NB code)
- Box in ABS, IP55
wastek PRO
wastek PRO
BLUETOOTH WI-FI MODULE FOR APP
BMS dry contacts module
RS485 MODBUS MODULE
PRESSURISATION
FILLING
✔
EMPTYING
✔
DRAINAGE

CONNECTIVITY
APPLICATIONS
RS485
(Optional)
UNIQUE APP



AIR PRESSURE SENSOR
KEY FEATURES
MODELS
Wastek PRO 1
CONNECTION DIAGRAMS

Wastek PRO 2
CONNECTION DIAGRAMS

CONNECTION DIAGRAMS
CONNECTION DIAGRAMS
EXPANSIONS
Codice
Modello