Optimizing consumption, canceling mechanical stress, avoiding annoying water hammers and controlling everything with a display is now possible with Vartek Plus, the Elentek control panel with extremely high quality performance.

From 2706 €

CUSTOMISATION

average rating is 5 out of 5

EASY INSTALLATION

average rating is 4 out of 5

VERSATILITY

average rating is 4 out of 5

MAIN FEATURES

MAIN FEATURES

  • Auxiliaries contacts and circuits in low voltage;
  • Normally open contact for start with selector in “Manual” position;
  • Normally open contact for minimum level/pressure contact;
  • Selector for Auto-Off-Manual operation (MANUAL stable): - Manual: costant operation at 50Hz with input from pressure switch; - Automatic: operation in modulation with analog sensor;
  • Analog input 4-20mA (0-10V on request);
  • Electronic frequency inverter with: - multifunction LCD - internal ventilation - “pid” regulation - connection for RS232/485 - 1st and 2nd ambient EMC filter - max distance of the motor up to 5.5 KW: 100 meters - max distance of the motor up to 37 KW: 200 meters - max distance of the motor up to 220 KW: 300 meters
  • Auxiliaries and motor protection fuses;
  • Isolator;
  • Forced ventilation kit;
  • Metallic box, IP54;
  • Ambient temperature: -5/+40 °C;
  • Relative humidity 50% at 40 °C (not condensed).

Vartek Plus

VERSIONS

  • VARTEK PLUS 1

  • VARTEK PLUS 2

  • VARTEK PLUS 3

POWER SUPPLY

  • Power supply 3~50/60 Hz 400V ±10% - output 3~400V;

Vartek Plus

Model Vartek Plus 1 electromechanical control panel with inverter

VARTEK PLUS 1

• Normally open contact for start;

• Normally open contact for minimum level/

pressure contact;

• Selector for Auto-Off-Manual (stable) operation:

- Manual: direct operation without controls;

- Automatic: operation controlled by min input and start input;

• Green led indicating motor running;

• Red led indicating motor overload;

• Line, star and delta contactors in AC3;

• Overload thermal relay internally restorable;

• Adjustable star/delta timer.

Model Vartek Plus 2 electromechanical control panel with inverter

Vartek Plus 2

• 2 Normally open contacts for start;

• 2 Normally open contacts for minimum level/pressure contact;

• 2 Selectors for Auto-Off-Manual (stable) operation:

- Manual: direct operation without controls;

- Automatic: operation controlled by min input and start input;

• 2 Green led indicating motor running;

• 2 Red led indicating motor overload;

• 2 Line, star and delta contactors in AC3;

• 2 Overload thermal relays internally restorable;

• 2 Adjustable star/delta timers.

Model Vartek Plus 2 electromechanical control panel with inverter

Vartek Plus 3

• 3 Normally open contacts for start;

• 3 Normally open contacts for minimum level/pressure contact;

• 3 Selectors for Auto-Off-Manual (stable) operation:

- Manual: direct operation without controls;

- Automatic: operation controlled by min input and start input;

• 3 Green led indicating motor running;

• 3 Red led indicating motor overload;

• 3 Line, star and delta contactors in AC3;

• 3 Overload thermal relays internally restorable;

• 3 Adjustable star/delta timers.

Vartek Plus

Vartek plus Electromechanical inverter control panel

CONNECTIVITY

APPLICATIONS

DOWNLOAD

Image by Adi Goldstein
Select an option

PRIVACY

I declare to be at least sixteen, and if less than sixteen, to have been authorized by the holder of parental responsibility, therefore I consent to the processing of my personal data as indicated in the Privacy Policy.

COMMUNICATIONS
I consent to the processing of my personal data for receiving newsletters, communications via telephone (SMS, WhatsApp, voice call). Informative contact form and information request.

Would you like more information?
  Contact us for a quote and find out the  discounted price reserved for you!  

KEY FEATURES

Components and applications

VARTEK PLUS control panel have a multifunctional display, a manual or automatic selector switch, and a switch-disconnector with door lock system.

A terminal block allows connection to external consumers and controls such as pressure switches, float switches, etc.



VARTEK PLUS control panels are optimal in various applications with:

  • Industrial water pumps, booster pumps
  • Rainwater lifting pumps, irrigation pumps (submersible or surface)
  • Submersible pumps, waste water pumps
What an inverter is made up of

Inverter start-up

A frequency converter is an electronic device used to control the rotational speed and torque of an electric motor. The motor, in turn, drives a load (e.g. a pump). A frequency converter converts the mains AC voltage into DC voltage via a rectifier and is stabilised by the DC link capacitor bank. The inverter finally converts the DC voltage back into AC with variable frequency. Frequency inverters for primary water and waste water treatment applications are equipped with various customised functions for controlling single and multi-pump systems.

How does an inverter works

WHAT CAN'T MISS

General alarm relay

RA

COD:

98016

General alarm relay

Kit of 3 level probes (electrodes)

K3SL

COD:

98007

Kit of 3 level probes (electrodes)

Relay for logic of automation

RLOG-…

COD:

98015*

Relay for logic of automation

Level relay for automation

RL-…

COD:

98006*

Level relay for automation

MODELS 

Load more model

Vartek Plus 1

Load more model

CONNECTION DIAGRAMS

Vartek Plus 2

Load more model

CONNECTION DIAGRAMS