top of page

MON - FRI 8.30-12.30 and 13.30-17.30

sfondo prodotto con onda.png
image-from-rawpixel-id-2354220-original_edited_edited.png

Vartek Plus

Inverter start-up

Optimizing consumption, canceling mechanical stress, avoiding annoying water hammers and controlling everything with a display is now possible with Vartek Plus, the Elentek control panel with extremely high quality performance.

From 2706 €

CUSTOMISATION

average rating is 5 out of 5

EASY INSTALLATION

average rating is 4 out of 5

VERSATILITY

average rating is 4 out of 5

MAIN FEATURES

MAIN FEATURES

  • Auxiliaries contacts and circuits in low voltage;
  • Normally open contact for start with selector in “Manual” position;
  • Normally open contact for minimum level/pressure contact;
  • Selector for Auto-Off-Manual operation (MANUAL stable): - Manual: costant operation at 50Hz with input from pressure switch; - Automatic: operation in modulation with analog sensor;
  • Analog input 4-20mA (0-10V on request);
  • Electronic frequency inverter with: - multifunction LCD - internal ventilation - “pid” regulation - connection for RS232/485 - 1st and 2nd ambient EMC filter - max distance of the motor up to 5.5 KW: 100 meters - max distance of the motor up to 37 KW: 200 meters - max distance of the motor up to 220 KW: 300 meters
  • Auxiliaries and motor protection fuses;
  • Isolator;
  • Forced ventilation kit;
  • Metallic box, IP54;
  • Ambient temperature: -5/+40 °C;
  • Relative humidity 50% at 40 °C (not condensed).

Vartek Plus

VERSIONS

  • VARTEK PLUS 1

  • VARTEK PLUS 2

  • VARTEK PLUS 3

POWER SUPPLY

  • Power supply 3~50/60 Hz 400V ±10% - output 3~400V;

Vartek Plus

Model Vartek Plus 1 electromechanical control panel with inverter

VARTEK PLUS 1

• Normally open contact for start;

• Normally open contact for minimum level/

pressure contact;

• Selector for Auto-Off-Manual (stable) operation:

- Manual: direct operation without controls;

- Automatic: operation controlled by min input and start input;

• Green led indicating motor running;

• Red led indicating motor overload;

• Line, star and delta contactors in AC3;

• Overload thermal relay internally restorable;

• Adjustable star/delta timer.

Model Vartek Plus 2 electromechanical control panel with inverter

Vartek Plus 2

• 2 Normally open contacts for start;

• 2 Normally open contacts for minimum level/pressure contact;

• 2 Selectors for Auto-Off-Manual (stable) operation:

- Manual: direct operation without controls;

- Automatic: operation controlled by min input and start input;

• 2 Green led indicating motor running;

• 2 Red led indicating motor overload;

• 2 Line, star and delta contactors in AC3;

• 2 Overload thermal relays internally restorable;

• 2 Adjustable star/delta timers.

Model Vartek Plus 2 electromechanical control panel with inverter

Vartek Plus 3

• 3 Normally open contacts for start;

• 3 Normally open contacts for minimum level/pressure contact;

• 3 Selectors for Auto-Off-Manual (stable) operation:

- Manual: direct operation without controls;

- Automatic: operation controlled by min input and start input;

• 3 Green led indicating motor running;

• 3 Red led indicating motor overload;

• 3 Line, star and delta contactors in AC3;

• 3 Overload thermal relays internally restorable;

• 3 Adjustable star/delta timers.

Vartek Plus

Vartek plus Electromechanical inverter control panel

CONNECTIVITY

APPLICATIONS

DOWNLOAD

Image by Adi Goldstein

Would you like more information?
  Contact us for a quote and find out the  discounted price reserved for you!  

Scegli un opzione
Azienda
Privato

PRIVACY

Dichiaro di avere compiuto sedici anni, e se minore di sedici, di essere stato autorizzato dal titolare della responsabilità genitoriale, pertanto acconsento al trattamento dei miei dati personali così come indicato nella Privacy Policy.

COMUNICAZIONI

Acconsento al trattamento dei miei dati personali. Per l’inoltro della newsletter, le comunicazioni via telefono (sms, WhatsApp, telefonata vocale). Informativa modulo contatti e richiesta informazioni.

KEY FEATURES

Components and applications

VARTEK PLUS control panel have a multifunctional display, a manual or automatic selector switch, and a switch-disconnector with door lock system.

A terminal block allows connection to external consumers and controls such as pressure switches, float switches, etc.



VARTEK PLUS control panels are optimal in various applications with:

  • Industrial water pumps, booster pumps
  • Rainwater lifting pumps, irrigation pumps (submersible or surface)
  • Submersible pumps, waste water pumps
What an inverter is made up of

Inverter start-up

A frequency converter is an electronic device used to control the rotational speed and torque of an electric motor. The motor, in turn, drives a load (e.g. a pump). A frequency converter converts the mains AC voltage into DC voltage via a rectifier and is stabilised by the DC link capacitor bank. The inverter finally converts the DC voltage back into AC with variable frequency. Frequency inverters for primary water and waste water treatment applications are equipped with various customised functions for controlling single and multi-pump systems.

How does an inverter works

WHAT CAN'T MISS

General alarm relay

RA

COD:

98016

General alarm relay

Kit of 3 level probes (electrodes)

K3SL

COD:

98007

Kit of 3 level probes (electrodes)

Relay for logic of automation

RLOG-…

COD:

98015*

Relay for logic of automation

Level relay for automation

RL-…

COD:

98006*

Level relay for automation

MODELS 

Vartek Plus 1

Code

01120P

Model

VARTEK PLUS 1/1,1

Voltage

3~400

Capacitor

Maximum power

1,1

Kw

Hp

1,5

Current

Range

Max

3,3

Box

H x L x W

Dimensions

700X510X290

Material

Metallic

Weight Kg.

16

Code

01121P

Model

VARTEK PLUS 1/1,5

Voltage

3~400

Capacitor

Maximum power

1,5

Kw

Hp

2

Current

Range

Max

4

Box

H x L x W

Dimensions

700X510X290

Material

Metallic

Weight Kg.

16

Code

01122P

Model

VARTEK PLUS 1/2,2

Voltage

3~400

Capacitor

Maximum power

2.2

Kw

Hp

3

Current

Range

Max

5.6

Box

H x L x W

Dimensions

700X510X290

Material

Metallic

Weight Kg.

16

Code

01123P

Model

VARTEK PLUS 1/3

Voltage

3~400

Capacitor

Maximum power

3

Kw

Hp

4

Current

Range

Max

7.2

Box

H x L x W

Dimensions

700X510X290

Material

Metallic

Weight Kg.

16

Code

01124P

Model

VARTEK PLUS 1/4

Voltage

3~400

Capacitor

Maximum power

4

Kw

Hp

5.5

Current

Range

Max

9,4

Box

H x L x W

Dimensions

700X510X290

Material

Metallic

Weight Kg.

16

CONNECTION DIAGRAMS

Vartek Plus 2

Code

2131

Model

VARTEK PLUS 2/30

Voltage

3~400

Capacitor

Maximum power

30

Kw

Hp

40

Current

Range

Max

62

Box

H x L x W

Dimensions

1000X810X340

Material

Metallic

Weight Kg.

52

Code

2132

Model

VARTEK PLUS 2/37

Voltage

3~400

Capacitor

Maximum power

37

Kw

Hp

50

Current

Range

Max

73

Box

H x L x W

Dimensions

1000X810X340

Material

Metallic

Weight Kg.

70

Code

2133

Model

VARTEK PLUS 2/45

Voltage

3~400

Capacitor

Maximum power

45

Kw

Hp

60

Current

Range

Max

88

Box

H x L x W

Dimensions

1000X810X340

Material

Metallic

Weight Kg.

90

Code

2134

Model

VARTEK PLUS 2/55

Voltage

3~400

Capacitor

Maximum power

55

Kw

Hp

75

Current

Range

Max

86

Box

H x L x W

Dimensions

1200X810X340

Material

Metallic

Weight Kg.

100

Code

2135

Model

VARTEK PLUS 2/75

Voltage

3~400

Capacitor

Maximum power

75

Kw

Hp

100

Current

Range

Max

45

Box

H x L x W

Dimensions

1800X1010X580

Material

Metallic

Weight Kg.

110

CONNECTION DIAGRAMS

Vartek Plus 3

Code

3131

Model

VARTEK PLUS 3/30

Voltage

3~400

Capacitor

Maximum power

30

Kw

Hp

40

Current

Range

Max

62

Box

H x L x W

Dimensions

1000X810X340

Material

Metallic

Weight Kg.

40

Code

3132

Model

VARTEK PLUS 3/37

Voltage

3~400

Capacitor

Maximum power

37

Kw

Hp

50

Current

Range

Max

73

Box

H x L x W

Dimensions

1000X810X340

Material

Metallic

Weight Kg.

40

Code

3133

Model

VARTEK PLUS 3/45

Voltage

3~400

Capacitor

Maximum power

45

Kw

Hp

60

Current

Range

Max

88

Box

H x L x W

Dimensions

1800X1010X580

Material

Metallic

Weight Kg.

100

Code

3134

Model

VARTEK PLUS 3/55

Voltage

3~400

Capacitor

Maximum power

55

Kw

Hp

75

Current

Range

Max

106

Box

H x L x W

Dimensions

1800X1010X580

Material

Metallic

Weight Kg.

120

Code

3135

Model

VARTEK PLUS 3/75

Voltage

3~400

Capacitor

Maximum power

75

Kw

Hp

100

Current

Range

Max

145

Box

H x L x W

Dimensions

1800X1010X580

Material

Metallic

Weight Kg.

130

CONNECTION DIAGRAMS

CONNECTION DIAGRAMS

ACCESSORIES

Codice

Modello

Descrizione

98006*

RL-…

Code

Model

Description

Level relay for automation

98007

K3SL

Code

Model

Description

Kit of 3 level probes (electrodes)

98015*

RLOG-….

Code

Model

Description

Relay for logic of automation

98016

RA

Code

Model

Description

General alarm relay

98021

PSS

Code

Model

Description

Start/stop pushbuttons

98022

FE

Code

Model

Description

Emergency pushbutton

98029

DT

Code

Model

Description

Daily timer with switch-riders

98030

WT

Code

Model

Description

Weekly digital timer

98031*

TMF

Code

Model

Description

Multifunction timer for logic

98032

TPL

Code

Model

Description

Pause/work timer

acoustic alarm
DAILY TIMER
Flashing alarm
Start/stop pushbuttons

EXPANSIONS

Codice

Modello

Descrizione

Battery backup

RELATED PRODUCTS

Codice

Modello

Descrizione

1500

UNIT ALARM 1

Code

Model

Description

Acoustic alarm panel with buffer battery

1501

UNIT ALARM 2

Code

Model

Description

Acoustic/visual alarm panel with buffer battery

1502

UNIT ALARM GSM

Code

Model

Description

Acoustic/visual alarm panel with buffer battery and GSM kit

1503

FLASH 12

Code

Model

Description

Acoustic/visual alarm panel

99020+...

MANIFOLD

Code

Model

Description

Stainless steel manifolds

alarm panel for anomalous signals
flash alarm device
applicazioni tipiche

TYPICAL APPLICATIONS

They say about us:

average rating is 4 out of 5

Affidabile anche con sbalzi di tensione

Uso Vartek Plus da un paio di mesi e regge bene anche quando la tensione della rete fa i capricci. L’ho montato senza difficoltà e da allora non ho più avuto falsi allarmi

Michele R.

6/11/25

bottom of page