Directo
Direct start-up
The direct start system is perhaps the simplest and most traditional and consists of connecting the engine directly to the mains supply, thus performing a full-voltage start.
It is often abbreviated to DOL (Direct On Line).
Direct starting is the simplest and most economical way to start electric pumps or motors and is the one traditionally used most.
They are suitable for starting small submersible pumps or submersible pumps or for pressure boosting systems with
surface pumps.
The control panel provides a direct connection to the mains, which implies:
- Starting at full voltage and constant frequency
- High starting torque
- Very short average acceleration times.
From 392 €
CUSTOMISATION
EASY INSTALLATION
VERSATILITY

MAIN FEATURES
MAIN FEATURES
- Automatic-0-Manual selector (stable):
- Manual: direct operation without controls;
- Automatic: operation with control from minimum and start inputs;
- Blue mains presence LED;
- Green LED for active motor ;
- Red LED for motor overload alarm;

VERSIONS
- Power supply 1 ~ 50/60Hz 230V±10% (DIRECTO-Mono);
- Power supply 3 ~ 50/60Hz 400V±10% (DIRECTO-Tri);
CONTROLS
- Internally resettable thermal overload relay;
- Line contactor in AC3;
PROTECTIONS
- 24 Vac transformer for auxiliary circuit;
- Low voltage inputs and control circuits;
- Auxiliary and motor protection with fuses;
- General door lock disconnect switch;
Directo

DIRECTO 1
- Normally open input for start command;
- Normally open input for minimum level/pressure command;
- Automatic-0-Manual (stable) selector:
- Manual: direct operation without controls;
- Automatic: operation with control from minimum and start inputs;
- Blue mains presence led;
- Green LED for active motor ;
- Red LED for motor overload alarm;
- Line contactor in AC3;
- Internally resettable thermal overload relay;
- ABS box up to 11 kW, 15 kW metal box, IP55.

DIRECTO 2
- 2 Normally open inputs for start command;
- 2 Normally open inputs for minimum level/pressure control;
- 2 Automatic-0-Manual (stable) selectors: - Manual: direct operation without controls;
- Automatic: operation with control from minimum and start inputs;
- Blue mains presence LED;
- 2 Green LEDs for active motor;
- Red LED for motor overload alarm;
- 2 Line contactors in AC3;
- 2 internally resettable thermal overload relays;
- ABS box up to 11 kW, metal box up to 15 kW, IP55.2 Normally open inputs for start command;
- 2 Normally open inputs for minimum level/pressure control;
- 2 Automatic-0-Manual (stable) selectors: - Manual: direct operation without controls;
- Automatic: operation with control from minimum and start inputs;
- Blue mains presence LED;
- 2 Green LEDs for active motor;
- Red LED for motor overload alarm;
- 2 Line contactors in AC3;
- 2 internally resettable thermal overload relays;
- ABS box up to 11 kW, metal box up to 15 kW, IP55.

DIRECTO 3
- 3 Normally open inputs for start command;
- 3 Normally open inputs for minimum level/pressure control;
- 3 Automatic-0-Manual (stable) selectors: - Manual: direct operation without controls;
- Automatic: operation with control from minimum and start inputs;
- Blue mains presence LEDs;
- 3 Green LEDs for active motor;
- Red LED for motor overload alarm;
- 3 Line contactors a in AC3;
- 3 internally resettable thermal overload relays;
- Metal casing, IP55.

Would you like more information?
Contact us for a quote and find out the discounted price reserved for you!

KEY FEATURES
Direct start-up
The direct start system is perhaps the simplest and most traditional and consists of connecting the engine directly to the mains supply, thus performing a full-voltage start. It is often abbreviated to DOL (Direct On Line).
The DIRECTO control panel provides a direct connection to the mains supply, which implies:
- Full voltage starting and constant frequency
- High starting torque
- Very short average acceleration times.

Components
DIRECTO control panels are manufactured in plastic or metal enclosures with a minimum protection rating of IP55.
Each switchboard has warning lights for voltage presence, thermal intervention and motor in operation, a manual or automatic selector switch, a disconnector switch with door lock system.
A terminal board allows connection to external utilities and controls such as pressure switches, floats, etc.


WHAT CAN'T MISS

SC-3P
COD:
98002
Relay for exchange on 3 motors

RL-…
COD:
98006*
Level relay for automation

K3SL
COD:
98007
Kit of 3 level probes (electrodes)

SC-2P
COD:
98001
Relay for exchange on 2 motors

MODELS
Directo 1
Code
1020
Model
DIRECTO 1-Mono/0.37
Voltage
1~230
Capacitor
Maximum power
0.37
Kw
Hp
0.5
Current
Range
4.2-5.7
Max
5.7
Box
H x L x W
Dimensions
320X240X190
Material
ABS
Weight Kg.
4
Code
1021
Model
DIRECTO 1-Mono/0.55
Voltage
1~230
Capacitor
Maximum power
0.55
Kw
Hp
1.15
Current
Range
5.7-7.6
Max
7.6
Box
H x L x W
Dimensions
320X240X190
Material
ABS
Weight Kg.
4
Code
1022
Model
DIRECTO 1-Mono/0.75
Voltage
1~230
Capacitor
Maximum power
1.15
Kw
Hp
1
Current
Range
7.6-9
Max
9
Box
H x L x W
Dimensions
320X240X190
Material
ABS
Weight Kg.
4
Code
1023
Model
DIRECTO 1-Mono/1.1
Voltage
1~230
Capacitor
Maximum power
1.1
Kw
Hp
1.5
Current
Range
10-12
Max
12
Box
H x L x W
Dimensions
320X240X190
Material
ABS
Weight Kg.
4
Code
1024
Model
DIRECTO 1-Mono/1.5
Voltage
1~230
Capacitor
Maximum power
1.5
Kw
Hp
2
Current
Range
13-16
Max
16
Box
H x L x W
Dimensions
320X240X190
Material
ABS
Weight Kg.
4
CONNECTION DIAGRAMS
Directo 2
Code
2020
Model
DIRECTO 2-Mono/0.37
Voltage
1~230
Capacitor
Maximum power
0.37
Kw
Hp
0.5
Current
Range
4.2-5.7
Max
5.7
Box
H x L x W
Dimensions
390X310X175
Material
ABS
Weight Kg.
7
Code
2021
Model
DIRECTO 2-Mono/0.55
Voltage
1~230
Capacitor
Maximum power
0.55
Kw
Hp
1.15
Current
Range
5.7-7.6
Max
7.6
Box
H x L x W
Dimensions
390X310X175
Material
ABS
Weight Kg.
7
Code
2022
Model
DIRECTO 2-Mono/0.75
Voltage
1~230
Capacitor
Maximum power
1.15
Kw
Hp
1
Current
Range
7.6-9
Max
9
Box
H x L x W
Dimensions
390X310X175
Material
ABS
Weight Kg.
7
Code
2023
Model
DIRECTO 2-Mono/1.1
Voltage
1~230
Capacitor
Maximum power
1.1
Kw
Hp
1.5
Current
Range
10-12
Max
12
Box
H x L x W
Dimensions
390X310X175
Material
ABS
Weight Kg.
7
Code
2024
Model
DIRECTO 2-Mono/1.5
Voltage
1~230
Capacitor
Maximum power
1.5
Kw
Hp
2
Current
Range
13-16
Max
16
Box
H x L x W
Dimensions
390X310X175
Material
ABS
Weight Kg.
7
CONNECTION DIAGRAMS
DIRECTO 3
Code
3020
Model
DIRECTO 3-Mono/0.37
Voltage
1~230
Capacitor
Maximum power
0.37
Kw
Hp
0.5
Current
Range
4.2-5.7
Max
5.7
Box
H x L x W
Dimensions
500X400X240
Material
Metallic
Weight Kg.
7
Code
3021
Model
DIRECTO 3-Mono/0.55
Voltage
1~230
Capacitor
Maximum power
0.55
Kw
Hp
1.15
Current
Range
5.7-7.6
Max
7.6
Box
H x L x W
Dimensions
500X400X240
Material
Metallic
Weight Kg.
7
Code
3022
Model
DIRECTO 3-Mono/0.75
Voltage
1~230
Capacitor
Maximum power
1.15
Kw
Hp
1
Current
Range
7.6-9
Max
9
Box
H x L x W
Dimensions
500X400X240
Material
Metallic
Weight Kg.
7
Code
3023
Model
DIRECTO 3-Tri/0.37
Voltage
3~400
Capacitor
Maximum power
0.37
Kw
Hp
0.5
Current
Range
1.0-1.3
Max
1.3
Box
H x L x W
Dimensions
500X400X240
Material
Metallic
Weight Kg.
14
Code
3024
Model
DIRECTO 3-Tri/0.55
Voltage
3~400
Capacitor
Maximum power
0.55
Kw
Hp
1.15
Current
Range
1.7-2.3
Max
2.3
Box
H x L x W
Dimensions
500X400X240
Material
Metallic
Weight Kg.
14
CONNECTION DIAGRAMS
CONNECTION DIAGRAMS

ACCESSORIES
Codice
Modello
Descrizione
98001
SC-2P
Code
Model
Description
Relay for exchange on 2 motors
98002
SC-3P
Code
Model
Description
Relay for exchange on 3 motors
98003*
AA-…V
Code
Model
Description
Acoustic alarm 90 dB
98004*
LL-…V
Code
Model
Description
Flashing alarm
98005
DBT
Code
Model
Description
Buffer battery kit for alarm
98006*
RL-…
Code
Model
Description
Level relay for automation
98007
K3SL
Code
Model
Description
Kit of 3 level probes (electrodes)
98008
VOLT
Code
Model
Description
Analog voltmeter 0-500v
98009
COM
Code
Model
Description
Voltmetric selector 4 positions 0-L1/L2-L2/L3-L1/L3 (0-R/S-S/T-R/T)
98010
AMP-25
Code
Model
Description
Ampmeter max 25A direct insertion





EXPANSIONS
Codice
Modello
Descrizione

RELATED PRODUCTS
Codice
Modello
Descrizione
1500
UNIT ALARM 1
Code
Model
Description
Acoustic alarm panel with buffer battery
1501
UNIT ALARM 2
Code
Model
Description
Acoustic/visual alarm panel with buffer battery
1502
UNIT ALARM GSM
Code
Model
Description
Acoustic/visual alarm panel with buffer battery and GSM kit
1503
FLASH 12
Code
Model
Description
Acoustic/visual alarm panel
99034
FLO 10
Code
Model
Description
Float switch with neoprene cable length 10 m
99036
DROP 10
Code
Model
Description
Variable float switch with neoprene cable length 10 m
99039
SHELL
Code
Model
Description
Counterweight





TYPICAL APPLICATIONS
They say about us:
Semplice e fa quello che serve
È proprio diretto: installazione veloce, comandi chiari e immediati
Paolo N.
4/12/22


_edited.webp)
_edited.webp)
_edited.webp)
_edited.webp)