MAIN FEATURES
MAIN FEATURES
- Transformer 24 Vac for auxiliary circuit;
- Auxiliaries contacts and circuits in low voltage;
- Blue led indicating mains supply;
- Normally open contact for start;
- Normally open contact for minimum level/pressure contact;
- Selector for Auto-Off-Manual (stable) operation: - Manual: direct operation without controls; - Automatic: operation controlled by min input and start input;
- Green led indicating motor running;
- Red led indicating motor overload;
- Line, star and delta contactors in AC3;
- Overload thermal relay internally restorable;
- Adjustable star/delta timer.
- Auxiliaries and motor protection fuses;
- Isolator;
- Enclosure in ABS up to 11KW, metallic box from 15KW, IP55;
- Ambient temperature: -5/+40 °C;
- Relative humidity 50% at 40 °C (not condensed).
VERSIONS
- STARDELTA 1
- STARDELTA 2
- STARDELTA 3
POWER SUPPLY
- Power supply 3~50/60Hz 400V ±10%;
Stardelta
STARDELTA 1
• Normally open contact for start;
• Normally open contact for minimum level/
pressure contact;
• Selector for Auto-Off-Manual (stable) operation:
- Manual: direct operation without controls;
- Automatic: operation controlled by min input and start input;
• Green led indicating motor running;
• Red led indicating motor overload;
• Line, star and delta contactors in AC3;
• Overload thermal relay internally restorable;
• Adjustable star/delta timer.
STARDELTA 2
• 2 Normally open contacts for start;
• 2 Normally open contacts for minimum level/pressure contact;
• 2 Selectors for Auto-Off-Manual (stable) operation:
- Manual: direct operation without controls;
- Automatic: operation controlled by min input and start input;
• 2 Green led indicating motor running;
• 2 Red led indicating motor overload;
• 2 Line, star and delta contactors in AC3;
• 2 Overload thermal relays internally restorable;
• 2 Adjustable star/delta timers.
STARDELTA 3
• 3 Normally open contacts for start;
• 3 Normally open contacts for minimum level/pressure contact;
• 3 Selectors for Auto-Off-Manual (stable) operation:
- Manual: direct operation without controls;
- Automatic: operation controlled by min input and start input;
• 3 Green led indicating motor running;
• 3 Red led indicating motor overload;
• 3 Line, star and delta contactors in AC3;
• 3 Overload thermal relays internally restorable;
• 3 Adjustable star/delta timers.
KEY FEATURES
Extra Stardelta
The range of electrical control panels STARDELTA is proposed as standard with ABS plastic box up to 11 KW, for higher powers the box is metal.
A number of accessories are available to customize your picture and enrich it with more controls and functions.
Benefits
The star start triangle reduces the current and the starting torque to 33% (1/3) of those found in a direct start.
During the start-up phase, the components are affected by currents below the rated motor current.
Starter star-triangle
The star triangle starter is the best known and perhaps the most widely used of the low-voltage starter methods.
It is used to start the pump motor reducing mechanical stress and limiting currents during start-up, all through a timed system that allows the switching of the control contactors installed inside the panel.
WHAT CAN'T MISS
SC-3P
COD:
98002
Relay for exchange on 3 motors
RL-…
COD:
98006*
Level relay for automation
K3SL
COD:
98007
Kit of 3 level probes (electrodes)
SC-2P
COD:
98001
Relay for exchange on 2 motors