Tekspeed
Frequency inverter for controlling a singlephase or three-phase pump, with wall mounting
Tekspeed is an electrical control and protection panel for a single-phase or three-phase pump with frequency inverter.
Available in versions with power supply:
•230vac single-phase input and 230vac single-phase output;
•Single-phase 230vac input and 230vac three-phase output;
•400vac three-phase input and 400vac three-phase output;
Tekspeed inverters can be mounted individually for the control of a pump, or in multipump systems up to 2 MASTER-SLAVE devices with alternating logic and contemporaneity.
From 780 €

MAIN FEATURES
MAIN FEATURES
- Frequency inverter with PID logic
- Multifunction LCD display for visualization: nominal pressure, voltage, current, frequency, working hours, number of starts and alarm history log
- Buttons for custom function selection and parameterization
- ART function (Automatic Reset Test). When the control panel is in dry run protection, ART tries, with a programmed periodicity, to restart the pump until the water flow is re-established
- STC function (Smart Temperature Control): when the temperature of the electronic board exceeds 85º C automatically decreases the frequency of revolution of the pump, decreasing the heat generation, while maintaining the flow of water
- Automatic system recovery after power failure. The system restarts maintaining the configuration parameters
- MASTER-SLAVE operation mode where up to 2 devices can be connected in cascade and start-up sequence alternating
- Configurable electronic input for: external level control, assigning a second pressure setpoint, remote control start-stop
- Input for external pressure transducer with 4-20 mA signal
- Aluminium heat sink with forced ventilation
Multifunctional LCD control panel
- Indication LEDs, START-STOP, AUTOMATIC buttons
- Configuration system

PROTECTIONS
- Electric pump control and protection system against overcurrent.
- Dry running protection system of the electric pump.
- Abnormal supply voltage.
- Short circuit between system output phases.
- Pressure transducer error alarm.
Tekspeed

Would you like more information?
Contact us for a quote and find out the discounted price reserved for you!

KEY FEATURES

WHAT CAN'T MISS

MODELS
Version
1112 MM
Code
99400
Input voltage
~1 x 230 Vac
Output voltage
~1 x 230 Vac
Frequency
50/60 Hz
Max. current
12 A
Overcurrent
20% 10”
Pressure range
0.5 ÷ 25 bar
Protection degree
IP65
Analog input
4-20 mA
Ambient temperature Max.
50 ºC
Weight
3,5 kg
Cooling system
Forced ventilation
Version
1010 MT
Code
99401
Input voltage
~1 x 230 Vac
Output voltage
~3 x 230 Vac
Frequency
50/60 Hz
Max. current
10 A
Overcurrent
20% 10”
Pressure range
0.5 ÷ 25 bar
Protection degree
IP65
Analog input
4-20 mA
Ambient temperature Max.
50 ºC
Weight
4.5kg
Cooling system
Forced ventilation
Version
1305TT
Code
99402
Input voltage
~3 x 400 Vac
Output voltage
~3 x 400 Vac
Frequency
50/60 Hz
Max. current
5A - 9A - 14A
Overcurrent
20% 10”
Pressure range
0.5 ÷ 25 bar
Protection degree
IP65
Analog input
4-20 mA
Ambient temperature Max.
50 ºC
Weight
4.5kg
Cooling system
Forced ventilation
Version
1309TT
Code
99403
Input voltage
~3 x 400 Vac
Output voltage
~3 x 400 Vac
Frequency
50/60 Hz
Max. current
5A - 9A - 14A
Overcurrent
20% 10”
Pressure range
0.5 ÷ 25 bar
Protection degree
IP65
Analog input
4-20 mA
Ambient temperature Max.
50 ºC
Weight
4.5kg
Cooling system
Forced ventilation
Version
1314TT
Code
99404
Input voltage
~3 x 400 Vac
Output voltage
~3 x 400 Vac
Frequency
50/60 Hz
Max. current
5A - 9A - 14A
Overcurrent
20% 10”
Pressure range
0.5 ÷ 25 bar
Protection degree
IP65
Analog input
4-20 mA
Ambient temperature Max.
50 ºC
Weight
4.5kg
Cooling system
Forced ventilation

CONNECTION DIAGRAMS