express PRO

The expression of completeness?
EXPRESS PRO, even in this new version, confirms itself as the most complete, versatile, and practical dashboard in the Elentek range.
With its simple and intuitive user interface and multiple applications, Express Pro has further evolved with additional connectivity, control, and expandability options.
MAXIMUM MODULARITY
System implementable up to 4 pumps
PROGRAMMABLE ANTI-SEIZE
Customisable programming to avoid undesired blockages
ALWAYS PRESENT
Every operation is shown on the multilingual display
FLEXIBILITY
Multiple inputs available for several applications
From 279 €
EASY INSTALLATION
EXPANDABILITY
USER INTERFACE
VERSATILITY
MAIN FEATURES
MAIN FEATURES
- LCD display for displaying and programming: voltage, current, power factor, hours of operation, number of starts, motor status, alarms, analogue signal and thresholds
- AUTOMATIC - 0 (standby) - MANUAL (fixed or pulse) operation buttons
- Language settings (Italian, English, French, Spanish, German)
- Anti-seize autotest (programmable)
- Dry running protection with: level probes/ floats/ pressure switches and minimum current
- Up to 6 control inputs: floats/pressure switches
- Input for 4-20 mA or 0-10V analogue signal
- Unit of measurement analogue signal cm - m - bar
- Emergency start and stop inputs with analogue signal operation mode (can be disabled)
- Clickson thermal pad inputs with automatic reset (can be disabled)
- Inversion of inputs (from normally open to normally closed)
- Automatic reset for minimum current alarm with 4 programmable times
- Activation delay from mains return (can be disabled)
- Manual button operation (fixed or pulse)
- Predisposition for run capacitors
EXPRESS PRO 2-3-4 ADDITIONAL FUNCTIONS
- Duty/standby (can be disabled)
- Immediate motor changeover in case of a fault

VERSIONS
- Power supply 1 phase 100-240Vac 50/60Hz (EASY-Mono)
- Power supply 3 phase 310-450Vac 50/60Hz (EASY-Tri/5.5)
CONTROLS
- Electronic minimum and maximum voltage monitoring
- Electronic maximum motor current monitoring
- Electronic dry-running monitoring for minimum current or cosφ
- Missing or incorrect phase sequence monitoring at power input (can be disabled)
ALARMS
- Alarms reported: voltage status, levels, motor overload, minimum motor current, clicson motor
- Alarms history
- Alarms for too many starts/hour (programmable)
- General alarm output contacts
- Alarm Output Contacts
PROTECTIONS
- Auxiliary and motor protection fuses
- Isolator (except for NB code)
- Box in ABS, IP55
express PRO
express PRO
WATER IN OIL CHAMBER MODULE
BLUETOOTH WI-FI MODULE FOR APP
BUFFER BATTERY MODULE
BMS dry contacts module
LEVEL PROBES MODULE
RS485 MODBUS MODULE
✔
PRESSURISATION
✔
FILLING
✔
EMPTYING
✔
DRAINAGE

CONNECTIVITY
APPLICATIONS
RS485
(Optional)
ALARM HISTORY



EXPANDABILITY
MODULAR
KEY FEATURES
MODELS
Express PRO 1
CONNECTION DIAGRAMS

Express PRO 2
CONNECTION DIAGRAMS

Express PRO 3
CONNECTION DIAGRAMS
Express PRO 4
CONNECTION DIAGRAMS
EXPANSIONS
Codice
Modello
Descrizione