![sfondo prodotto con onda.png](https://static.wixstatic.com/media/2aa156_d1ab936619094034994323df23b35dd6~mv2.png/v1/fill/w_123,h_87,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/2aa156_d1ab936619094034994323df23b35dd6~mv2.png)
![image-from-rawpixel-id-2354220-original_edited_edited.png](https://static.wixstatic.com/media/2aa156_b726a92b5d47403593e2733f46a2429f~mv2.png/v1/fill/w_123,h_110,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/2aa156_b726a92b5d47403593e2733f46a2429f~mv2.png)
![Minivar Electric inverter control panel](https://static.wixstatic.com/media/2989e0_797dae8f50f7491092a91cdcb5d7f606~mv2.png/v1/fill/w_490,h_535,al_c,lg_1,q_85,enc_auto/smart%20pro.png)
Minivar
INVERTER START
Inverter starting in a minimalist control panel. Optimization prevails with Elentek's Minivar series in every detail, from energy saving to performance.
Compactness made as Electric panel.
From 913 €
EASY INSTALLATION
CUSTOMISATION
VERSATILITY
FUNCTIONS
Auxiliaries contacts and circuits in low voltage;
Normally open contact for start with selector in “Manual” position;
Normally open contact for min level/pressure;
Analog input 4-20mA (0-10V on request);
Selector Auto-0-Man (manual permanent):
- Manual: operation at 50 Hz constant with pressure switch control;
- Automatic: operation in modulation with analog sensor;Electronic frequency inverter with:
- Multifunction LCD
- Internal ventilation
- “PID” regulation
- Connection for RS232/485
- 2nd ambient EMC filter
- Max distance of the motor: 50 metersAuxiliaries and motor protection fuses;
ABS box, IP54;
Ambient temperature: -5/+40 °C;
Relative humidity 50% at 40 °C (not condensed).
![Minivar](https://static.wixstatic.com/media/2989e0_797dae8f50f7491092a91cdcb5d7f606~mv2.png/v1/fill/w_101,h_110,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/smart%20pro.png)
VERSIONS
SINGLE-PHASE INPUT 230V - THREE-PHASE OUTPUT 230V
THREE-PHASE 230V INPUT - THREE-PHASE 230V OUTPUT
400V THREE-PHASE INPUT - 400V THREE-PHASE OUTPUT
POWER SUPPLY
Power supply 1~50/60 Hz 230V ±10% - output 3~230V;
Power supply 3~50/60 Hz 230V ±10% - output 3~230V;
Power supply 3 ~50/60Hz 400v ±10% - output 3 ~ 400V
![](https://static.wixstatic.com/media/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg/v1/fill/w_24,h_13,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg)
CARATTERISTICHE PRINCIPALI
Minivar
Minivar
![Image by Adi Goldstein](https://static.wixstatic.com/media/nsplsh_4555735677454f73626c45~mv2_d_7360_4912_s_4_2.jpg/v1/fill/w_147,h_98,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/nsplsh_4555735677454f73626c45~mv2_d_7360_4912_s_4_2.jpg)
![](https://static.wixstatic.com/media/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg/v1/fill/w_24,h_13,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg)
CARATTERISTICHE CHIAVE
Inverter start-up
A frequency converter is an electronic device used to control the rotational speed and torque of an electric motor. The motor, in turn, drives a load (e.g. a pump). A frequency converter converts the mains AC voltage into DC voltage via a rectifier and is stabilised by the DC link capacitor bank. The inverter finally converts the DC voltage back into AC with variable frequency. Frequency inverters for primary water and waste water treatment applications are equipped with various customised functions for controlling single and multi-pump systems.
![How does an inverter works](https://static.wixstatic.com/media/2989e0_6bf49fea1e324bf7a36284dfccd1b839~mv2.png/v1/fill/w_59,h_64,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/cc4567_106a21855ac4485b9c252690aeb0b9a4_mv2.png)
Components and applications
MINIVAR control panel have a multifunctional display, a manual or automatic selector switch, and a switch-disconnector with door lock system.
A terminal block allows connection to external consumers and controls such as pressure switches, float switches, etc.
MINIVAR control panels are optimal in various applications with:
Industrial water pumps, booster pumps
Rainwater lifting pumps, irrigation pumps (submersible or surface)
Submersible pumps, waste water pumps
![What an inverter is made up of](https://static.wixstatic.com/media/2989e0_47d1bcf3710d48bca70cd2811810a10f~mv2.png/v1/fill/w_59,h_64,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/cc4567_106a21855ac4485b9c252690aeb0b9a4_mv2.png)
![](https://static.wixstatic.com/media/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg/v1/fill/w_24,h_13,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg)
COSA NON PUÓ MANCARE
![External 24Vac input for activation/deactivation of the motor](https://static.wixstatic.com/media/2989e0_4b7f84bd36d1435ea1dcd79a536c1a12~mv2.png/v1/fill/w_103,h_112,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/sonde%20livello_edited.png)
CI24V
COD:
98033
External 24Vac input for activation/deactivation of the motor
![Kit of 3 level probes (electrodes)](https://static.wixstatic.com/media/2989e0_a0a1868e66324c83bf9482b66eac7f89~mv2.png/v1/fill/w_112,h_112,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/sonde%20livello_edited.png)
K3SL
COD:
98007
Kit of 3 level probes (electrodes)
![Stop device for low pressure](https://static.wixstatic.com/media/2989e0_fcb362805d3548928e381d2da382b79c~mv2.png/v1/fill/w_103,h_112,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/sonde%20livello_edited.png)
DA-B PRESS
COD:
98063
Stop device for low pressure
![Level relay for automation](https://static.wixstatic.com/media/2989e0_2278bb6d57ff4c8687cee3a275e09128~mv2.png/v1/fill/w_103,h_112,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/sonde%20livello_edited.png)
RL-…
COD:
98006*
Level relay for automation
![](https://static.wixstatic.com/media/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg/v1/fill/w_24,h_13,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg)
MODELLI
230V SINGLE-PHASE INPUT - 230V THREE-PHASE OUTPUT
SCHEMI DI COLLEGAMENTO
THREE-PHASE 230V INPUT - THREE-PHASE 230V OUTPUT
SCHEMI DI COLLEGAMENTO
400V THREE-PHASE INPUT - 400V THREE-PHASE OUTPUT
SCHEMI DI COLLEGAMENTO
SCHEMI DI COLLEGAMENTO
![](https://static.wixstatic.com/media/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg/v1/fill/w_24,h_13,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg)
TUTTI GLI ACCESSORI
Codice
Modello
Descrizione
![](https://static.wixstatic.com/media/cc4567_ee718a33f4754a1381905168c89cd166~mv2.jpg/v1/fill/w_24,h_13,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/cc4567_ee718a33f4754a1381905168c89cd166~mv2.jpg)
ESPANSIONI
Codice
Modello
Descrizione
![](https://static.wixstatic.com/media/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg/v1/fill/w_24,h_13,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/2aa156_2636226f1c4b4a72b9ba071550478eb3~mv2.jpg)
PRODOTTI CORRELATI
Codice
Modello
Descrizione
![](https://static.wixstatic.com/media/cc4567_ee718a33f4754a1381905168c89cd166~mv2.jpg/v1/fill/w_24,h_13,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/cc4567_ee718a33f4754a1381905168c89cd166~mv2.jpg)