Directo - Control panel with direct start

Directo

DIRECT START

The direct start system is perhaps the simplest and most traditional and consists of connecting the engine directly to the mains supply, thus performing a full-voltage start.

It is often abbreviated to DOL (Direct On Line).

Direct starting is the simplest and most economical way to start electric pumps or motors and is the one traditionally used most.

They are suitable for starting small submersible pumps or submersible pumps or for pressure boosting systems with

surface pumps.

The control panel provides a direct connection to the mains, which implies:

  • Starting at full voltage and constant frequency

  • High starting torque

  • Very short average acceleration times.

From 392 €

EASY INSTALLATION

la calificación promedio es 4 de 5

CUSTOMISATION

la calificación promedio es 5 de 5

VERSATILITY

la calificación promedio es 5 de 5

FUNCTIONS

  • Automatic-0-Manual selector (stable):

  • Manual: direct operation without controls;

  • Automatic: operation with control from minimum and start inputs;

  • Blue mains presence LED;

  • Green LED for active motor ;

  • Red LED for motor overload alarm;

Directo

VERSIONS

  • Power supply 1 ~ 50/60Hz 230V±10% (DIRECTO-Mono);

  • Power supply 3 ~ 50/60Hz 400V±10% (DIRECTO-Tri);

CONTROLS

  • Internally resettable thermal overload relay;

  • Line contactor in AC3;

PROTECTIONS

  • 24 Vac transformer for auxiliary circuit;

  • Low voltage inputs and control circuits;

  • Auxiliary and motor protection with fuses;

  • General door lock disconnect switch;

CARACTERISTICAS PRINCIPALES

Directo

Model Directo 1 electromechanical pump panel

DIRECTO 1

  • Normally open input for start command;

  • Normally open input for minimum level/pressure command;

  • Automatic-0-Manual (stable) selector:

  • Manual: direct operation without controls;

  • Automatic: operation with control from minimum and start inputs;

  • Blue mains presence led;

  • Green LED for active motor ;

  • Red LED for motor overload alarm;

  • Line contactor in AC3;

  • Internally resettable thermal overload relay;

  • ABS box up to 11 kW, 15 kW metal box, IP55.

Model Directo 2 electromechanical pump panel

DIRECTO 2

  • 2 Normally open inputs for start command;

  • 2 Normally open inputs for minimum level/pressure control;

  • 2 Automatic-0-Manual (stable) selectors: - Manual: direct operation without controls;

  • Automatic: operation with control from minimum and start inputs;

  • Blue mains presence LED;

  • 2 Green LEDs for active motor;

  • Red LED for motor overload alarm;

  • 2 Line contactors in AC3;

  • 2 internally resettable thermal overload relays;

  • ABS box up to 11 kW, metal box up to 15 kW, IP55.

Model Directo 3 electromechanical pump panel

DIRECTO 3

  • 3 Normally open inputs for start command;

  • 3 Normally open inputs for minimum level/pressure control;

  • 3 Automatic-0-Manual (stable) selectors: - Manual: direct operation without controls;

  • Automatic: operation with control from minimum and start inputs;

  • Blue mains presence LEDs;

  • 3 Green LEDs for active motor;

  • Red LED for motor overload alarm;

  • 3 Line contactors a in AC3;

  • 3 internally resettable thermal overload relays;

  • Metal casing, IP55.

Directo

Directo - Control panel with direct start

CONECTIVIDAD

APPLICACIONES


DOWNLOAD

Image by Adi Goldstein
Seleccione una opción

PRIVACY

Declaro que soy mayor de dieciséis años, y si soy menor de dieciséis, que he sido autorizado por el titular de la patria potestad, por lo que consiento el tratamiento de mis datos personales tal y como se indica en la Privacy Policy.

COMUNICACION

Autorizo el tratamiento de mis datos personales. Para el envío del boletín de noticias, comunicación por teléfono (sms, WhatsApp, llamada de voz). Formulario de contacto y solicitud de información.

¿Quieres más info? 

  ¡Contáctenos para una cotización y descubra el precio con descuento reservado para usted!  

CARACTERISTICAS CLAVE

Components

DIRECTO control panels are manufactured in plastic or metal enclosures with a minimum protection rating of IP55.

Each switchboard has warning lights for voltage presence, thermal intervention and motor in operation, a manual or automatic selector switch, a disconnector switch with door lock system.

A terminal board allows connection to external utilities and controls such as pressure switches, floats, etc.

Electronic board and components for a direct start panel

Direct start-up

The direct start system is perhaps the simplest and most traditional and consists of connecting the engine directly to the mains supply, thus performing a full-voltage start. It is often abbreviated to DOL (Direct On Line).

The DIRECTO control panel provides a direct connection to the mains supply, which implies:

- Full voltage starting and constant frequency 

- High starting torque 

- Very short average acceleration times.

Direct start key components

LO QUE NO PUEDE FALTAR

Relay for exchange on 3 motors

SC-3P

COD:

98002

Relay for exchange on 3 motors

Level relay for automation

RL-…

COD:

98006*

Level relay for automation

Kit of 3 level probes (electrodes)

K3SL

COD:

98007

Kit of 3 level probes (electrodes)

Exchanger for two pumps

SC-2P

COD:

98001

Relay for exchange on 2 motors

MODELOS

Cargar otros modelos

Directo 1

Cargar otros modelos

DIAGRAMAS DE CONEXION

Directo 2

Cargar otros modelos

DIAGRAMAS DE CONEXION

Directo 3

Cargar otros modelos

DIAGRAMAS DE CONEXION

Cargar otros modelos

DIAGRAMAS DE CONEXION

TODOS LOS ACCESSORIOS

Codigo

Modelo

Descripcion

EXPANSIONES

Codigo

Modelo

Descripcion

PRODUCTOS RELACIONADOS

Codigo

Modelo

Descripcion

applicazioni tipiche

APPLICACIONES TIPICAS

bottom of page