Directo
DIRECT START
The direct start system is perhaps the simplest and most traditional and consists of connecting the engine directly to the mains supply, thus performing a full-voltage start.
It is often abbreviated to DOL (Direct On Line).
Direct starting is the simplest and most economical way to start electric pumps or motors and is the one traditionally used most.
They are suitable for starting small submersible pumps or submersible pumps or for pressure boosting systems with
surface pumps.
The switchgear provides a direct connection to the mains, which implies:
- Starting at full voltage and constant frequency
- High starting torque
- Very short average acceleration times.
EASY INSTALLATION
CUSTIMISATION
VERSATILITY
FUNCTIONS
Automatic-0-Manual selector (stable):
Manual: direct operation without controls;
Automatic: operation with control from minimum and start inputs;
Blue mains presence LED;
Green LED for active motor ;
Red LED for motor overload alarm;

VERSIONS
Power supply 1 ~ 50/60Hz 230V±10% (DIRECTO-Mono);
Power supply 3 ~ 50/60Hz 400V±10% (DIRECTO-Tri);
CONTROLS
Internally resettable thermal overload relay;
Line contactor in AC3;
PROTECTIONS
24 Vac transformer for auxiliary circuit;
Low voltage inputs and control circuits;
Auxiliary and motor protection with fuses;
General door lock disconnect switch;

CARATTERISTICHE PRINCIPALI
Directo

DIRECTO 1
Normally open input for start command;
Normally open input for minimum level/pressure command;
Automatic-0-Manual (stable) selector:
Manual: direct operation without controls;
Automatic: operation with control from minimum and start inputs;
Blue mains presence led;
Green LED for active motor ;
Red LED for motor overload alarm;
Line contactor in AC3;
Internally resettable thermal overload relay;
ABS box up to 11 kW, 15 kW metal box, IP55.

DIRECTO 2
2 Normally open inputs for start command;
2 Normally open inputs for minimum level/pressure control;
2 Automatic-0-Manual (stable) selectors: - Manual: direct operation without controls;
Automatic: operation with control from minimum and start inputs;
Blue mains presence LED;
2 Green LEDs for active motor;
Red LED for motor overload alarm;
2 Line contactors in AC3;
2 internally resettable thermal overload relays;
ABS box up to 11 kW, metal box up to 15 kW, IP55.

DIRECTO 3
3 Normally open inputs for start command;
3 Normally open inputs for minimum level/pressure control;
3 Automatic-0-Manual (stable) selectors: - Manual: direct operation without controls;
Automatic: operation with control from minimum and start inputs;
Blue mains presence LEDs;
3 Green LEDs for active motor;
Red LED for motor overload alarm;
3 Line contactors a in AC3;
3 internally resettable thermal overload relays;
Metal casing, IP55.
Directo


CARATTERISTICHE CHIAVE
Components
DIRECTO control panels are manufactured in plastic or metal enclosures with a minimum protection rating of IP55.
Each switchboard has warning lights for voltage presence, thermal intervention and motor in operation, a manual or automatic selector switch, a disconnector switch with door lock system.
A terminal board allows connection to external utilities and controls such as pressure switches, floats, etc.

Applications
Direct starting is the simplest and most economical way to start electric pumps or motors, and is traditionally the most widely used. The current induced in the rotor is high. This results in a peak current on the mains which can be 5 to 8 times the rated current. They are suitable for starting small submersible pumps or for pressure boosting systems with surface pumps.

Direct start-up
The direct start system is perhaps the simplest and most traditional and consists of connecting the engine directly to the mains supply, thus performing a full-voltage start. It is often abbreviated to DOL (Direct On Line).
The DIRECTO switchgear provides a direct connection to the mains supply, which implies:
- Full voltage starting and constant frequency
- High starting torque
- Very short average acceleration times.


COSA NON PUÓ MANCARE
Level relay for emptying
COD:
RL-S
Level relay for emptying

Float DROP
COD:
DROP 20
Variable buoyancy float with 20 meters of cable

Relay for exchange on 2 motors
COD:
SC-2P
Relay for exchange on 2 motors

Float FLO
COD:
FLO 20
Float with 20m neoprene cable