General technical features

  • Multiple power sources: AC power supply, 24V or 48V
    batteries;

  • Power supply 1 ~ 50/60 Hz 230V ± 10%;

  • Pure sine wave output 1 ~ 50/60 Hz 230V ± 10%;

  • Configurable via LCD display;

  • Auto restart when mains power returns;

  • Overload / over temperature / short circuit protection;

  • Optimized charge process for perfect battery
    performance;

  • Electric panel for pump/user control.

Download

 

PRIVACY

I declare that I am sixteen years old, and if I am under sixteen, that I have been authorized by the holder of parental responsibility, therefore I consent to the processing of my personal data as indicated in the Privacy Policy .

COMMUNICATIONS

I agree to the treatment of my personal data. For the forwarding of the newsletter, communications via telephone (sms, WhatsApp, voice call)

More  info?

You can ask us for information or a quote to find out the discounted price dedicated to you.

Highlights

 
3_prova (Grande).jpg

Operation

The principle of operation of HELP SINUS is based on the batteries’ power supply in situations of black-out from other energy sources. 

HELP SINUS converts the 24V/48V batteries voltage into 230V voltage using the inverter and supplying electric power to the units connected to it (electric pumps or any other single-phase device).

AdobeStock_113877825 (Grande).jpeg

Applications

The check-up of the system is made easy and quick by the LCD displaying constantly the messages about the operation and occurring alarms.
In addition, the integrated auto-test function allows to keep the pumps functioning and ready to the intervention.

 

_MG_7087 (Grande).jpg

Installation & service 

HELP SINUS è estremamente semplice da installare e necessita di una manutenzione minima, ovvero del controllo periodico delle batterie e dell’eventuale sostituzione al termine della “vita” degli accumulatori.

 

 

The solutions we propose

Models

HELP SINUS

 

  • Power supply 1 ~ 50/60 Hz 230V ±10%

  • Pure sine wave output 1 ~ 50/60 Hz 230V ±10%

  • Automatic battery charger

  • Control panel for the control of the user:

  • Power supply 1phase 100-240Vac 50/60Hz

  • Input for 3 single-pole probes (COM-MIN-MAX) or start/stop float switches;

  • Input G.A. normally open for alarm activation;

  • G/P1 normally open input;

  • T1 input for motor clicson;

  • Push-buttons for selecting operation AUTOMATIC-0-MANUAL(temporary);

  • DIP-SWITCH selectors for:

    • enabling level alarm from probes;

    • thermal cut-out activation delay 5/10 seconds;

    • alarm output settings;

    • alarm reset enable from motor clicson;

    • filling/emptying mode;

    • enabling start/stop float function;

    • delay of electronic board activation on power mains return;

  • Autotest anti-seize (2 sec. every 48 hours);

  • Green led: power ON;

  • Green led: automatic mode enabled;

  • Green led: motor active;

  • Red led: motor overload alarm/minimum current alarm;

  • Red led: motor clicson activation alarm;

  • Red led: level alarm from probes or GA input;

  • Electronic control of max current due to overload, with
    assisted calibration;

  • Electronic control of minimum current due to dry run, with
    assisted calibration;

  • Automatic reset due to minimum current alarm;

  • Timer for delay of motor enabling on power mains return;

  • Protection of auxiliary circuits and motor with fuses;

  • Cumulative alarm output with voltage-free contacts
    (COM-NO-NC resistive load - 5A / 250V);

  • Cumulative alarm output, live (12Vcc / 100mA);

  • Isolator;

  • Provision for run capacitors (not included);

  • Box in ABS, IP55;

  • Ambient temperature: -5/+40 °C;

  • Relative humidity 50% at 40 °C (condensate free).

 

System for the control of 1 user

System for the control of 2 users

HELP SINUS

+ DUO (A-B-C)

 

  • Power supply 1 ~ 50/60 Hz 230V ±10%

  • Pure sine wave output 1 ~ 50/60 Hz 230V ±10%

  • Automatic battery charger

  • Control panel for the control of 2 users:

  • Power supply 1phase 100-240Vac 50/60Hz

  • Input for 3 single-pole probes (COM-MIN-MAX) or start/stop float switches;

  • Input G.A. normally open for alarm activation;

  • G/P1 and G/P2 normally open input;

  • T1 and T2 input for motor clicson;

  • Push-buttons for selecting operation AUTOMATIC-0-MANUAL(temporary);

  • DIP-SWITCH selectors for:

    • enabling level alarm from probes;

    • thermal cut-out activation delay 5/10 seconds;

    • alarm output settings;

    • alarm reset enable from motor clicson;

    • filling/emptying mode;

    • enabling start/stop float function;

    • delay of electronic board activation on power mains return;

    • DIP-SWITCH selector #8 for enabling motors exchange;

  • Autotest anti-seize (2 sec. every 48 hours);

  • Green led: power ON;

  • Green led: automatic mode enabled;

  • 2 Green led: motor active;

  • 2 Red led: motor overload alarm/minimum current alarm;

  • 2 Red led: motor clicson activation alarm;

  • Red led: level alarm from probes or GA input;

 

  • Electronic control of max current due to overload, with assisted calibration;

  • Electronic control of minimum current due to dry run, with assisted calibration;

  • Automatic reset due to minimum current alarm;

  • Timer for delay of motor enabling on power mains return;

  • Protection of auxiliary circuits and motor with fuses;

  • Cumulative alarm output with voltage-free contacts (COM-NO-NC resistive load - 5A / 250V);

  • Cumulative alarm output, live (12Vcc / 100mA);

  • Isolator;

  • Provision for run capacitors (not included);

  • Box in ABS, IP55;

  • Ambient temperature: -5/+40 °C;

  • Relative humidity 50% at 40 °C (condensate free).

 

DUO A

 

  • Pumps exchange operation

  • Simultaneous operation with mains supply

  • Operation with 1 pump only in black-out conditions

 

DUO B

 

  • Pumps exchange operation

  • Simultaneous operation with mains supply and in black-out conditions (choose the model of HELP SINUS to cover the total current of the 2 pumps)

 

DUO C

 

  • Pumps exchange operation 

  • Simultaneous operation with mains supply

  • Operation of 1 pump only in black-out conditions

  • Automatic activation of the 2nd pump in case of trip of the 1st pump

 

Models

Help Sinus 9

Battery backup system for users up to 9A

Help Sinus 18

Battery backup system for users up to 18A

Duo function

Accessories

 
  • CSF380

    Controllo sequenza e mancanza fasi

  • CI24V / CI230V

    Comando esterno per attivazione/spegnimento utenza

  • TPL

    Timer pausa/lavoro

  • WT

    Timer settimanale digitale

  • DT

    Timer giornaliero

  • TMF

    Timer multifunzione

  • PSS

    Pulsante start/stop

  • DBT

    Dispositivo per allarme con batteria in tampone

  • LL

    Allarme lampeggiante luminoso

  • AA

    Allarme acustico 90dB

  • COM-A

    Commutatore amperometrico

  • AMP

    Amperometro

  • COM

    Selettore voltmetrico 4 posizioni

  • VOLT

    Voltmetro analogico 0-500V

  • RL

    Level relay for automation

  • SC-3P

    Relé alternanza 3 motori

  • SC-2P

    Relé alternanza 2 motori

  • K3SL

    Kit 3 sonde di livello unipolari

Discover our products

Find out how we do it

Support

30 Motivated people

The strength of our company is our staff. 30 highly qualified and motivated people who manage even the most difficult challenges by working together, because together nothing is impossible.

About Us:

Address

Via A. Meucci, 5-11, 35028

Piove di Sacco (PD) - Italia

Working      Hours 

Monday          08-12 / 13.30-17.30

Tuesday         08-12 / 13.30-17.30

Wednesday    08-12 / 13.30-17.30

Thursday        08-12 / 13.30-17.30

Friday              08-12 / 13.30-17.30

Saturday        closed

Sunday           closed

Contacts

Copyright 2019 - Elentek srl

VAT no. 04534630282

Cap. Soc. i.v. 100.000€

More info?

We will reply as soon as possible!

PRIVACY

I declare to be at least sixteen, and if less than sixteen to have been authorized by the holder of parental responsibility, therefore I consent to the processing of my personal data as indicated in the Privacy Policy.

COMMUNICATION

I consent to the processing of my personal data. For the transmission of newsletters, communication via telephone (SMS, WhatsApp, voice call)

MON - FRI 8.00-12.00 and 13.30-17.30