Reacto

STARTING AT IMPEDANCE

Electric control panels suitable for starting submersible pumps even of large powers or pumping systems for irrigation systems with withdrawal from deep wells.

From 1440 €

CUSTOMISATION

average rating is 5 out of 5

EASY INSTALLATION

average rating is 4 out of 5

VERSATILITY

average rating is 4 out of 5

MAIN FEATURES

  • 24 Vac transformer for auxiliary circuit;
  • Low voltage inputs and control circuits;
  • Input normally open for start-up control;
  • Normally open input for minimum level/pressure control;
  • Automatic Selector-0-Manual (manual stable):
  • - Manual: direct operation without controls;
  • - Automatic: operation with control from minimum and starting inputs;
  • Blue led network presence;
  • Green led of active motor;
  • Red led overload motor alarm;
  • State reactance 4 starts now of which 2 consecutive;
  • Thermal overload relay internally restorable;
  • Adjustable reactance timer;
  • Line transmitters and starting impedance in AC3;
  • Auxiliary protection and motor with fuses;
  • General disconnector block door;
  • Metal casing, IP55;
  • Ambient temperature: -5/+40  ;
  • Relative humidity 50% at 40 ºC (not condensed).

Reacto

VERSIONS

  • REACTO 1

POWER SUPPLY

  • Power supply 3~50/60Hz 400V ±10%;

MAIN FEATURES

Reacto

Reacto

Reacto - Electromechanical control panels Impedance  start

CONNECTIVITY

APPLICATIONS

DOWNLOAD

Image by Adi Goldstein

KEY FEATURES

Extra Reacto

The entire REACTO serie is offered as standard with metal box IP55, are then available a whole series of accessories and optional including double door box and fiberglass casings.

Discover all the extras for the Reacto

Impedance start-up

Starting with stator reactors is suitable for electric pumps with cage rotor motor in which the voltage drop is produced by reactors placed in series at the stator during the starting phase.

The starting current is limited to about half of what you would have with the start at full voltage. At the end of the acceleration phase, the reactors are excluded (controlled by a timer) and the motor returns to the full voltage parameters.

Watch the impedance start-up

WHAT CAN'T MISS

Analog voltmeter 0-500v

VOLT

COD:

98008

Analog voltmeter 0-500v

Level relay for automation

RL-…

COD:

98006*

Level relay for automation

Kit of 3 level probes (electrodes)

K3SL

COD:

98007

Kit of 3 level probes (electrodes)

Voltmeter for control panels

COM

COD:

98009

4-position voltmeter selector switch

MODELS 