Directo
Direct start-up
The direct start system is perhaps the simplest and most traditional and consists of connecting the engine directly to the mains supply, thus performing a full-voltage start.
It is often abbreviated to DOL (Direct On Line).
Direct starting is the simplest and most economical way to start electric pumps or motors and is the one traditionally used most.
They are suitable for starting small submersible pumps or submersible pumps or for pressure boosting systems with
surface pumps.
The control panel provides a direct connection to the mains, which implies:
- Starting at full voltage and constant frequency
- High starting torque
- Very short average acceleration times.
From 392 €
CUSTOMISATION
EASY INSTALLATION
VERSATILITY
MAIN FEATURES
- Automatic-0-Manual selector (stable):
- Manual: direct operation without controls;
- Automatic: operation with control from minimum and start inputs;
- Blue mains presence LED;
- Green LED for active motor ;
- Red LED for motor overload alarm;
VERSIONS
- Power supply 1 ~ 50/60Hz 230V±10% (DIRECTO-Mono);
- Power supply 3 ~ 50/60Hz 400V±10% (DIRECTO-Tri);
CONTROLS
- Internally resettable thermal overload relay;
- Line contactor in AC3;
PROTECTIONS
- 24 Vac transformer for auxiliary circuit;
- Low voltage inputs and control circuits;
- Auxiliary and motor protection with fuses;
- General door lock disconnect switch;
MAIN FEATURES
Directo
DIRECTO 1
- Normally open input for start command;
- Normally open input for minimum level/pressure command;
- Automatic-0-Manual (stable) selector:
- Manual: direct operation without controls;
- Automatic: operation with control from minimum and start inputs;
- Blue mains presence led;
- Green LED for active motor ;
- Red LED for motor overload alarm;
- Line contactor in AC3;
- Internally resettable thermal overload relay;
- ABS box up to 11 kW, 15 kW metal box, IP55.
DIRECTO 2
- 2 Normally open inputs for start command;
- 2 Normally open inputs for minimum level/pressure control;
- 2 Automatic-0-Manual (stable) selectors: - Manual: direct operation without controls;
- Automatic: operation with control from minimum and start inputs;
- Blue mains presence LED;
- 2 Green LEDs for active motor;
- Red LED for motor overload alarm;
- 2 Line contactors in AC3;
- 2 internally resettable thermal overload relays;
- ABS box up to 11 kW, metal box up to 15 kW, IP55.2 Normally open inputs for start command;
- 2 Normally open inputs for minimum level/pressure control;
- 2 Automatic-0-Manual (stable) selectors: - Manual: direct operation without controls;
- Automatic: operation with control from minimum and start inputs;
- Blue mains presence LED;
- 2 Green LEDs for active motor;
- Red LED for motor overload alarm;
- 2 Line contactors in AC3;
- 2 internally resettable thermal overload relays;
- ABS box up to 11 kW, metal box up to 15 kW, IP55.
DIRECTO 3
- 3 Normally open inputs for start command;
- 3 Normally open inputs for minimum level/pressure control;
- 3 Automatic-0-Manual (stable) selectors: - Manual: direct operation without controls;
- Automatic: operation with control from minimum and start inputs;
- Blue mains presence LEDs;
- 3 Green LEDs for active motor;
- Red LED for motor overload alarm;
- 3 Line contactors a in AC3;
- 3 internally resettable thermal overload relays;
- Metal casing, IP55.
Directo
KEY FEATURES
Direct start-up
The direct start system is perhaps the simplest and most traditional and consists of connecting the engine directly to the mains supply, thus performing a full-voltage start. It is often abbreviated to DOL (Direct On Line).
The DIRECTO control panel provides a direct connection to the mains supply, which implies:
- Full voltage starting and constant frequency
- High starting torque
- Very short average acceleration times.
Components
DIRECTO control panels are manufactured in plastic or metal enclosures with a minimum protection rating of IP55.
Each switchboard has warning lights for voltage presence, thermal intervention and motor in operation, a manual or automatic selector switch, a disconnector switch with door lock system.
A terminal board allows connection to external utilities and controls such as pressure switches, floats, etc.
WHAT CAN'T MISS
SC-3P
COD:
98002
Relay for exchange on 3 motors
RL-…
COD:
98006*
Level relay for automation
K3SL
COD:
98007
Kit of 3 level probes (electrodes)
SC-2P
COD:
98001