General technical features

  • Power supply 1~50/60 Hz 230V ±10% (DRYTEK 1-Mono);

  • Power supply 3~50/60 Hz 400V ±10% (DRYTEK 1-Tri);

  • Normally open contact for start;

  • Pushbuttons for selecting operation and set up;

  • Displaying of: volt, ampere, motor power factor (COS Ø) and alarms;

  • Green led indicating motor running;

  • Adjustable electronic control for motor overload;

  • Motor’s control on 2 phases;

  • Auto-restore from protection with 4 independently settable times 0÷250 minutes;

  • Protection from:

    • motor overcurrent (adjustable)

    • phase failure/loss

    • min/max voltage (adjustable)

    • max current (adjustable)

    • dry running power factor (pf adjustable)

  • Auxiliaries and motor protection fuses;

  • Alarm output (NC-C-NO resistive load 5A / 250V);

  • Main switch interlocking door;

  • Provision for run capacitor for single-phase version (not included);

  • Enclosure in ABS, IP55;
    Ambient temperature: -5/+40 °C;

  • Relative humidity 50% at 40 °C (not condensed). 

Download

 

PRIVACY

I declare to be at least sixteen, and if less than sixteen, to have been authorized by the holder of parental responsibility, therefore I consent to the processing of my personal data as indicated in the Privacy Policy.

COMMUNICATIONS
I consent to the processing of my personal data for receiving newsletters, communications via telephone (SMS, WhatsApp, voice call)

More info?

Find out the discounted price dedicated to you

Highlights

 

Electronic board and components

Drytek contains an electronic main board with microprocessor and external LCD for reading the parameters  set and the alarms status.
The motor protection fuses are supplied as a standard and can be replaced by circuit breaker on request.
An isolator switch cuts the main power supply input to cut-off voltage to the panel and guarantees max safety when opening the control panel.

Functions  indications

The DRYTEK series is equipped with a practical LCD for reading the operating and alarm status, in addition it has LED lights and pushbuttons for setting and control on the frontpanel.
The main screen shows in any time the electrical quantities measured by DRYTEK: 
-    Voltage power supply;
-    Current consumption of the connected load;
-    Power factor of the connected load (cos-fi);
-    Manual or automatic operation mode.

Set-up

Any set-up, control and use operation is done on the frontpanel  without opening the enclosure of the panel.
5 languages are available in the software (Italian, English, French, Spanish, German).
The system is simple, fast and intuitive.

Settable parameters

By pressing the SETUP button and holding it down for a few seconds, you access the user programming menu.
In the first screen you can set the minimum value of the power factor below which the load is deactivated for dry running protection.
In the second you can set the maximum motor current value above which the motor is deactivated for overcurrent protection.
4 interval times can be set for automatic restart with the possibility of making it cyclical.

Alarms

The DRYTEK electronic board has an alarm output with volt free contacts which activates for all the alarm status of which the system is equipped: dry running (power factor), maximum current, voltage too low, voltage too high, lack / phase sequence (three-phase model only).

 

Applications

Filling

with float switch

DRYTEK application for filling with float switch and dry running protection by power factor control.

Pressurization/ Irrigation

with pressure switch

DRYTEK application for pressurization or irrigation with pressure switch and  dry running protection by power factor control. 

 

Models

Accessories

 
  • CI24V / CI230V

    External control for activation deactivation of the motor

  • TPL

    Pause/work timer

  • WT

    Weekly digital timer

  • DT

    Daily timer

  • TMF

    Multifunction timer

  • DBT

    Buffer battery kit for alarm

  • LL

    Flashing alarm

  • AA

    Acoustic alarm 90dB

  • RL

    Relé di livello per automatismo

Connection drawings

 

Discover our products

Find out how we do it

Support

30 Motivated people

The strength of our company is our staff. 30 highly qualified and motivated people who manage even the most difficult challenges by working together, because together nothing is impossible.

About Us:

Address

Via A. Meucci, 5-11, 35028

Piove di Sacco (PD) - Italia

Working      Hours 

Monday          08-12 / 13.30-17.30

Tuesday         08-12 / 13.30-17.30

Wednesday    08-12 / 13.30-17.30

Thursday        08-12 / 13.30-17.30

Friday              08-12 / 13.30-17.30

Saturday        closed

Sunday           closed

Contacts

Copyright 2019 - Elentek srl

VAT no. 04534630282

Cap. Soc. i.v. 100.000€

More info?

We will reply as soon as possible!

PRIVACY

I declare to be at least sixteen, and if less than sixteen to have been authorized by the holder of parental responsibility, therefore I consent to the processing of my personal data as indicated in the Privacy Policy.

COMMUNICATION

I consent to the processing of my personal data. For the transmission of newsletters, communication via telephone (SMS, WhatsApp, voice call)

MON - FRI 8.00-12.00 and 13.30-17.30