Filling
with float switch and dry running protection by power factor control
1. SCOUT / SMART EVO 1 / DRYTEK / EXPRESS
2. Tank
3. Start float switch
4. Deep well pump
Suitable panels
The control panels suitable for this application are:
1. SCOUT in filling function and dry running protection by minimum current control
2. SMART EVO 1 in filling function and dry running protection by minimum current control
3. DRYTEK in filling function and dry running protection by power factor control
4. EXPRESS 1 in filling function and dry running protection by power factor control
Pressurization/ irrigation
with pressure switch and level probes
1. SCOUT / SMART EVO 1 / EXPRESS 1
2. Start pressure switch
3. Single-pole level probes
4. Deep well pump
Suitable panels
The control panels suitable for this application are:
1. SCOUT in emptying function and dry running protection by level probes
2. SMART EVO 1 in emptying function and dry running protection by level probes
3. EXPRESS 1 in emptying function and dry running protection by level probes
Pressurization/ irrigation
with pressure switch and dry run protection without probes
1. SCOUT / SMART EVO 1 / DRYTEK / EXPRESS 1 2. Start pressure switch
3. Deep well pump
Suitable panels
The control panels suitable for this application are:
1. SCOUT in filling function and dry running protection by minimum current control
2. SMART EVO 1 in filling function and dry running protection by minimum current control
3. DRYTEK in funzione riempimento e protezione marcia a secco da controllo cos-fi
4. EXPRESS 1 in filling function and dry running protection by power factor control
Emptying
clear water
with float switches
1. SCOUT x2 / SMART EVO 2 / EXPRESS 2
2. Tank
3. Start 2nd motor float switch
4. Start 1st motor float switch
5. Stop motor float switch
6. Surface pumps
Suitable panels
The control panels suitable for this application are:
1. N.02 SCOUT connected in series in emptying function
2. SMART EVO 2 in emptying function and dry run protection by float switches
3. EXPRESS 2 in emptying function and dry run protection by float switches
Pressurization
with pressure switches and dry run protection by float switches
1. SCOUT x2 / SMART EVO 2 / EXPRESS 2
2. Start pressure switch
3. Dry run float switch
4. Tank
5. Surface pumps
Suitable panels
The control panels suitable for this application are:
1. n.02 SCOUT connected in series in emptying function
2. SMART EVO 2 in emptying function and dry run protection by float switches
3. EXPRESS 2 in emptying function and dry run protection by float switches
Drainage
sewage water
2 pumps with float switches
1. DRAIN 2 / SMART EVO 2
2. Stop float switch
3. Start 1st motor float switch
4. Start 2nd motor float switch
5. Alarm float switch
6. Submersible pumps
Suitable panels
The control panels suitable for this application are:
1. DRAIN 2 specific for drainage systems
2. SMART EVO 2 in emptying function and dry run protection by float switches
Emptying
with 4-20mA electronic level sensor
1. EXPRESS 1 / WASTEK 1
2. Electronic level sensor 4-20 mA
3. Surface pump
Suitable panels
The control panels suitable for this application are:
1. EXPRESS 1 in emptying function
2. WASTEK 1 in emptying function
Pressurization/ irrigation
with 4-20mA electronic level sensor and dry run protection without probes
1. EXPRESS 1
2. 4-20 mA electronic pressure transducer
3. Pump with dry run by power factor control
Suitable panels
The control panels suitable for this application are:
1. EXPRESS 1 in emptying function
Emptying
with air pressure sensor
1. WASTEK 1
2. Air pressure level sensor (1 m)
3. Surface pump
Suitable panels
The control panels suitable for this application are:
1. WASTEK 1 in emptying operation
Drainage
sewage water
with float switches
-
DRAIN 1 / SMART EVO 1
-
Motor stop float switch
-
Motor start float switch
-
Alarm float switch
-
Submersible pump
Suitable panels
The control panels suitable for this application are:
1. DRAIN 1 specific for drainage system
2. SMART EVO 1 in emptying function and dry run protection by float switches.
Filling tank
with probes and dry run protection by float switch
-
SCOUT / SMART EVO 1 / EXPRESS 1
-
Tank
-
Level probes for filling
-
Dry run float switch
-
Submersible pump
Suitable panels
The control panels suitable for this application are:
1. SCOUT in filling function and dry run protection by float switches
2. SMART EVO 1 in filling function and dry run protection by float switches
3. EXPRESS 1 in filling function and dry run protection by float switches
Filling tank
with float switches and dry run protection by level probes
1. SCOUT / SMART EVO 1 / EXPRESS 1
2. Tank
3. Float switch for filling
4. Dry run level probes
5. Surface pump
Suitable panels
The control panels suitable for this application are:
1. SCOUT in filling function and dry run protection by level probes
2. SMART EVO 1 in filling function and dry run protection by level probes
3. EXPRESS 1 in filling function and dry run protection by level probes
Pressurization/ irrigation
with pressure switch and dry run protection by float switch
1. SMART EVO 1 / EXPRESS 1
2. Start pressure switch
3. Dry run float switch
4. Surface pump
Suitable panels
The control panels suitable for this application are:
1. SMART EVO 1 in emptying function with float switch and dry run protection by float switch
2. EXPRESS 1 in emptying function with float switch and dry run protection by float switch
Pressurization/ irrigation
with pressure switch and dry run by flow switch
1. SCOUT
2. Dry run flow switch
3. Filling pressure switch
4. Surface pump
Suitable panels
The control panels suitable for this application are:
1. SCOUT in emptying function with pressure switch and dry run protection by flow switch